Summary of Contents

Page 1 - UV-2600/2700

UV-2600/2700UV-VIS SpectrophotometersC101-E121B

Page 2

Accessories have been prepared to accommodate a variety of applications such as temperature-controlled, micro-volume, and multisample measurements.Wit

Page 3 - Double monochromator UV-2700

11Automated Data ProcessingAnalysis Correspondence ChartAfter spectra are measured, the software can perform data processing automatically in conjunct

Page 4 - Enabling 8-Abs Measurements

A Wealth of Applications12Thickness Measurements of Cling FilmsBand Gap Measurements for Compound SemiconductorsDNA and Protein MeasurementsElectricit

Page 5 - 8-Abs Photometric Range

13An aqueous solution of hexavalent chromium was colored with a diphenylcarbazide reagent, and the absorption spectrum was then checked. It is eviden

Page 6 - Wavelength up to 1400 nm

UVProbe SoftwareAll-In-One SoftwareSpectrum ModulePhotometric ModuleReport GeneratorKinetics Module14UVProbe is an all-in-one software package equippe

Page 7

A Variety of Data Processing and Calculation Functions15Data processing operations, such as peak detection and area calculation, and data conversion o

Page 8 - Size Down

(Note) UVProbe software Ver. 2.00 or later is required.Optional SoftwareUVProbe Agent Software16The UVProbe Agent, which was developed for Shimadzu UV

Page 9 - User-Friendly

17Color Measurement SoftwareThis software calculates color values of the measurement sample from the spectrum measured.This software measures the thic

Page 10 - Accommodates Any Application

Accessories (Options)Cells18DescriptionOptical Path (L) Required Sample Volume Type Fused Silica (S) Glass (G)Square cellSquare cell with stopperSemi-

Page 11 - Analysis Correspondence Chart

19If using a 4-cell-type universal rectangular cell holder, use this as a reference-side cell holder if necessary.Holds two cylindrical cells with an

Page 12 - A Wealth of Applications

Experience the Precision Desired, in Any Situation

Page 13 - Vitamin MeasurementsFoods

Accessories (Options)20• Micro-volume samples can be measured. (Minimum sample volume: 50 L to 100 L)• Support for commercial microplates and micro

Page 14 - UVProbe Software

21Constant-Temperature Cell Holder(P/N 202-30858-04)• Temperature range: 5 °C to 90 °C (depends on the performance of the constant-temperature water c

Page 15 - Methods as Standard

22Accessories (Options)NTT-2200P Constant-Temperature Water Circulator(P/N 208-97263)Circulates temperature-controlled water to a constant-temperature

Page 16 - Optional Software

23ASC-5 Auto Sample Changer(P/N 206-23810-**)Combine with a sipper unit or syringe sipper to build an automated multisample spectrophotometry system.•

Page 17 - Color Measurement Software

Ref. lightMaskMaskMirror M3Mirror M2Mirror M1Sample light8°90°ø60integratingsphere7704501070600465580External viewOpticsSample (measuring surface do

Page 18 - Accessories

Construction of Absolute Reectance Attachment100 % lightMeasurementlightPolarizer positionSampleIntegrating sphereM2M2'M1M3Ref25Absolute Reecta

Page 19

Hardware SpecicationsInstallation Area Plan (UV-2600/2700)26ItemPhotometric systemPhotometric systemUV-2600Czerny-Turner mountingSingle monochromator

Page 20

Software Specications27(Note) UV Validation SoftwareUVProbe SoftwareOperating SystemData Acquisition ModesGeneralSpectrumModeDataProcessingin Spectru

Page 21 - TMSPC-8 Tm Analysis System

UV-2600/2700Printed in Japan 3655-02407-30ANSCompany names, product/service names and logos used in this publication are trademarks and trade names of

Page 22

Equipped with a single monochromator, providing low noise performance across a wide wavelength rangeEnables near-infrared measurements (up to 1400

Page 23 - (P/N 206-28300-41)

Lo-Ray-Ligh grade diffraction gratingAchieves Ultra-Low Stray Light, Enabling 8-Abs Measurements4Conventional models provide 5-Abs coverage. Even high

Page 24

Double monochromator UV-2700Performance with a Minimum 8-Abs Photometric RangeEquipped with a double monochromator that achieves ultra-low stray ligh

Page 25 - Analog Output Interface

Single monochromator UV-2600Integrating Sphere Enables Measurements to 1400 nmCapable of a Measurement Wavelength up to 1400 nmA key feature of the UV

Page 26 - Installation Area Plan

7Transmission Measurements of Polycrystalline Silicon Using the ISR-2600Plus UV-2600Relative Diffuse Reflection Measurements of an Anti-Reflective Fi

Page 27 - Software Specications

28 % Size Reductionin Comparison toConventional Models28% Size DownConventional model (UV-2450/2550)600 mm450 mm120mm60mmCompact 450 mm Width Size8Wit

Page 28

Even More Compact and User-FriendlyTo respond to feedback that conventional models are too large, we have challenged ourselves to maximize space savi

Comments to this Manuals

No comments